Roof ventilation moves outside air through the attic, in low at the eaves and out high near the ridge, so moisture that escapes from the house can leave before it condenses on the cold underside of the roof deck. With months of cool, wet weather here, that winter drying job is the one this guide is about. Oregon’s code sets how much vent area an attic needs, and a reroof is the easiest time to get it right.
Why do Portland attics get damp in winter?
Start with the weather. In NOAA’s 1991-2020 climate normals for Portland International Airport, the monthly mean temperature from November through March sits between about 42 and 48 degrees Fahrenheit, and each of those months has measurable precipitation on roughly 16 to 19 days: five months of cool, damp air above a heated, lived-in house.
The moisture that causes trouble mostly comes from below. The Building America Solution Center, run for the U.S. Department of Energy, explains that warm, moist air from the house leaks into the attic and condenses on cold surfaces such as the underside of the roof sheathing, often as frost in cold weather. The deck in a vented attic is cold, often below the dew point, so the two main defences are stopping that air leakage and providing proper intake and exhaust vents. Building Science Corporation adds one more cause: on clear nights a shingle roof loses heat to the sky and its deck can drop well below the air temperature, one reason frost can form in a cold, clear spell with no rain at all.
The leaks are ordinary. The Solution Center’s list includes gaps around wiring and recessed lights, plumbing stacks, flues and chimneys, attic hatches, bath fan housings, top plates and drywall seams. ENERGY STAR notes that in cold weather the result can show as frosty patches in the insulation, and the Solution Center warns that moisture which keeps condensing leads quickly to mold. Damp spread across a wide area, rather than the single stain of a leak, points to the house air; the roof leak page explains how a roofer tells the two apart.
Bath fans and dryer vents that end in the attic
A duct that stops short is a direct feed of moisture; the Department of Energy’s guide to durable attics calls venting into the attic “a major source of moisture”. Oregon’s residential code is direct about it: air removed by a mechanical exhaust system must be discharged outdoors, and “shall not be exhausted into an attic, soffit, ridge vent or crawl space” (M1501.1 in the 2023 Oregon Residential Specialty Code). Exhaust from bathrooms, toilet rooms and kitchens may not discharge into an attic (M1505.2), and a clothes dryer duct must carry its moisture to the outdoors and end outside the building (M1502.2, M1502.3).
Note the words soffit and ridge vent. A bath duct laid so it blows toward a soffit vent, or tucked under the ridge vent, is still venting into the attic. The Department of Energy’s weatherization job aid for bath fans says the same thing in plain terms: venting to the exterior does not include unconditioned attics or other spaces that are themselves ventilated to the outdoors, and moisture exhausted into an attic can cause mold and rot.
A reroof is the moment to fix it. With the old roofing off, a roofer can set a roof cap for the bath fan and give the duct a direct run to it, or the duct can go to a wall cap instead. Ask for it as a line on the bid.
What does Oregon’s code require for a vented attic?
The rules sit in section R806 of the Oregon Residential Specialty Code (chapter 8), with Oregon changes that matter here.
- Cross ventilation for every enclosed attic or rafter space, through openings that keep out rain, are screened to between 1/16 and 1/4 inch, and open directly to outside air (R806.1).
- Vent area. At least 1/150 of the area of the vented space, counted as net free area, the open area left after louvers and screens (R806.2).
- The 1/300 exception, Oregon style. The area may drop to 1/300 only if both conditions are met: a Class I or II vapor retarder on the warm side of the ceiling, and 40 to 50 percent of the required area in high vents no more than 3 feet below the ridge, with the rest in the bottom third of the attic. The model code applies the vapor-retarder condition only in the coldest climate zones; Oregon struck that limit, so here it always applies. If nobody can confirm that layer is in your ceiling, use 1/150.
- A clear path at the eaves. Insulation and blocking may not block eave vents, and there must be at least 1 inch of space between the insulation and the roof sheathing at the vent (R806.3). That is the job of baffles.
- Vents installed to the maker’s instructions (R806.4).
Oregon also ties this to reroofing. Where sheathing is replaced before a new roof covering goes on, ventilation in the affected areas must be provided to R806 (section R908.1.1, an Oregon amendment that is not in the model code), and every reroof must follow the roof covering maker’s instructions (R908.1). Those instructions ask for ventilation too: Malarkey’s instructions tell installers to put roof vents at the ridges and eaves and to meet FHA or HUD requirements and the adopted code.
The code also allows an unvented attic, but only under conditions in R806.5: the attic must sit wholly inside the insulated envelope, with insulation applied at the roofline in specified ways. That is a redesign of the insulation, not something a reroof does on its own.
Which edition? These sections are from the 2023 edition, checked against the Building Codes Division’s summary of amendments. The 2026 edition took effect on October 1, 2026, and until March 31, 2027 either edition may be used outside Chapter 1 (adoption page). Its full text is still being published, so it is not quoted here.
Vancouver is different. Washington adopts the 2021 model code with its own amendments, and its amendment slot for this section is marked reserved, so R806 applies as printed. Clark County is climate zone 4C in Washington’s energy code, outside the zones where the vapor-retarder condition applies, so in Vancouver the 1/300 ratio needs only the high-and-low vent split.
How to calculate attic ventilation
The arithmetic is short once you measure the right thing:
- Measure the attic floor, meaning the ceiling area under the attic, not the house’s living space. A two-story house is measured over the top floor only, and each separate attic or rafter space is counted on its own.
- Divide by 150, or by 300 if both Oregon conditions are met, and multiply by 144 to turn square feet into square inches of net free area.
- Split it high and low. At 1/300 the code wants 40 to 50 percent high. At 1/150 it sets no split, but the Building America Solution Center’s advice is an even division with exhaust never larger than intake.
- Divide by each vent’s rating. Net free area is printed on the product or its data sheet.
Here is the calculation for an attic floor of 2,000 square feet, using two ridge vents’ published ratings: 18 square inches per foot for GAF’s Cobra Rigid Vent 3 and 12.5 for Owens Corning’s VentSure Rigid Roll.
| 2,000 sq ft of attic floor | At 1/150 | At 1/300 (both conditions met) |
|---|---|---|
| Total net free area | 13.3 sq ft, or 1,920 sq in | 6.7 sq ft, or 960 sq in |
| High vents (exhaust) | Up to half: 960 sq in | 40 to 50 percent: 384 to 480 sq in |
| Low vents (intake) | At least half: 960 sq in | The rest: 480 to 576 sq in |
| Ridge vent rated 18 sq in per foot | About 53 feet of ridge | About 21 to 27 feet |
| Ridge vent rated 12.5 sq in per foot | About 77 feet of ridge | About 31 to 38 feet |
The ratio doubles or halves the answer, and the product rating moves it by nearly half again. If your ridge is shorter than the exhaust needs, the bid should say how the rest will be met without mixing vent types, and the eave intake has to deliver its share through clear baffles.
Ridge, box, gable or powered: which exhaust vent?
| Exhaust type | Where it sits | What to know |
|---|---|---|
| Ridge vent | A continuous slot along the peak, under a cap | Pairs with continuous eave intake; the length needed follows from its rating |
| Box vent (roof louver) | Individual openings near the top of the roof | Count them by rated area; for the 1/300 split they must be within 3 feet of the ridge |
| Gable vent | Louvers in the end walls | Federal guidance says not to combine them with a ridge vent |
| Turbine | A wind-spun cap on the roof | One of five exhaust types Air Vent says not to mix |
| Powered or solar fan | A motor-driven fan on the roof or a gable | See the cautions below |
The rule that ties the table together is to use one kind of exhaust per attic. The vent maker Air Vent says in its technical answers that “It is never OK to mix two different types of attic exhaust vents”, because one of them ends up acting as intake for the other, which can pull in weather and leaves the underside of the deck less evenly vented. The Building America Solution Center makes the same point about gable vents: used with ridge vents they are likely to short-circuit the airflow and can leave the soffit vents doing nothing. So a reroof that adds a ridge vent should close off the old box vents and gable louvers rather than leave them working against it.
Powered and solar attic fans: proceed with caution
Attic fans are sold as an upgrade, and the federal guidance is cool on them. The Building America Solution Center’s page on attic ventilation fans explains that a fan lowers the air pressure in the attic, which pulls air up from the living space through gaps in the ceiling. In winter that means warm, moist house air drawn into the attic, the reverse of what you want. The same page warns that fuel-burning appliances without sealed combustion may draft poorly or backdraft, that bath and kitchen fans lose effectiveness, that fans installed to cure winter moisture have in many cases proved ineffective or worse, and that ENERGY STAR does not recommend them. Its advice is passive vents. Solar fans work the same way on a smaller motor; the page notes they move less air and so create less suction, which reduces the effect rather than removing it.
What ventilation cannot fix
Vents carry away moisture that has reached the attic; they do not stop it arriving. HUD’s guide to moisture-resistant homes warns that if a lot of house air leaks into an attic, ventilation may not be enough to prevent condensation, and the Solution Center adds that more passive venting can make moisture worse when the ceiling below has not been air sealed first. The Department of Energy’s consumer guide to home ventilation puts the order plainly: seal the leaks between the living space and the attic, because insulation alone cannot prevent moisture problems.
In practice that means sealing the ceiling penetrations, the hatch and the top plates, and getting any bath or dryer duct outside, before adding vents or insulation. Building Science Corporation’s view is that a vented attic should be cut off from the house by an airtight ceiling, with ducts and air handlers ideally kept out of it. Air sealing happens from inside the attic, not from the roof, so ask whether it is part of the bid or a separate job.
What should a reroof bid say about ventilation?
A bid that says only “ventilation per code” leaves you nothing to check. Ask for these lines:
- What is there now: the intake and exhaust vents, their type, and any that are blocked or painted over.
- The attic floor area, the ratio used (1/150, or 1/300 with both conditions) and the resulting net free area, high and low.
- The vents to be installed, by product name and rated net free area.
- Which existing vents will be closed off so the attic has one type of exhaust.
- Baffles at the eaves wherever insulation is tight to the deck.
- Where every bath fan and the dryer will vent, and the caps for them.
- Whether replaced sheathing brings R908.1.1 into play.
The roof replacement page lists the rest of what a bid should itemize. On price, the cost page has no separate ventilation row, but the Portland-area replacement ranges it takes from Jobin Roofing assume, in that roofer’s words, a full tear-off “with proper ventilation”, so a much lower bid may have left it out. It matters for the warranty too: Malarkey’s technical bulletin says damage caused by a lack of ventilation is not covered by its shingle warranties.
Converting a cedar shake roof adds a solid deck, exactly the situation R908.1.1 covers, and the cedar shake roof guide walks through it. To have the attic and the roof checked on the same visit, request a free roof inspection.